Data Importing
                                                        
                                                    
                                                    
                                                                Enter or paste the raw OD measurement data in a 12x8 matrix, leaving a space between each value as shown in the example data (you can easily overwrite this when inputting your own)
                                                            
                                                        
                                                    
                                                        Paste your unedited OD data from a Word or Excel table into the text box below (Numeric format only)
                                                    
                                                
                                                
                                                        Standard Concentrations Settings
                                                        
                                                        
                                                            
                                                                
                                                        
                                                    
                                                
                                                                    For your standard concentration, enter the first (s1) or last (s6) standard concentration and select x2 or ÷2 depending on where you want the series calculations to start.
                                                                    A table with the standard series values will appear below this box once you click submit, check this is correct.
                                                                
                                                            
                                                            
                                                            7 Standards
                                                        
                                                        
                                                            
                                                            11 Standards
                                                        
                                                        
                                                            
                                                            Custom Standards
                                                        
                                                    
                                                                Initial standard concentration
                                                                
                                                                    
                                                                
                                                                
                                                                    
                                                                
                                                            
                                                        
                                                            Change Of Gradient
                                                            
                                                        
                                                        
                                                            Sample Replications:
                                                            
                                                        
                                                    
                                                    Well Assignment
                                                    
                                                
                                                
                                                            Ensure the “Well assignment” is laid out in the same way as the standards and samples of your experiment.
                                                            You can use our suggested templates as for 7 standards or 11 standards or customise the layout with options to include blanks and controls.
                                                        
                                                    
                                                Regression /Fitting model
                                                
                                                
                                                    
                                                        
                                                
                                                
                                            
                                            
                                                            Choose which regression model best fits your data. The standard concentrations and OD values will be automatically included from the previous tab.
                                                            Our recommended model for most ELISA experiments is the four-parameter logistic (4PL) curve fit.
                                                        
                                                    
                                                Standard concentrations
                                                
                                            
                                            
                                                Standard OD Values
                                                
                                            
                                        
                                                X data column
                                                
                                                
                                                    
                                                        
                                                
                                                
                                            
                                            
                                                            Most often, data fit best when plotted as logarithm (base 10). Select what is appropriate for your data set.
                                                        
                                                    
                                                Y data column
                                                
                                            
                                            
                                                Legend Name
                                                
                                            
                                            
                                                X axis Name
                                                
                                            
                                            
                                                Y axis Name
                                                
                                            
                                        
                                            
                                            Deduct background
                                            
                                            
                                                
                                                    
                                            
                                        
                                        
                                                        If your plate included blank replicates, tick the “deduct background” box to show the corrected values.
                                                    
                                                
                                                        Click submit to see the standard curve. You can also click the download button on the top right of the graph to save this to your computer as an image.
                                                        To use this curve to get results, you can hover your mouse over the curve to see the axis coordinate values
                                                    
                                                | Formula | |
|---|---|
| a value | |
| b value | |
| c value | |
| d value | 
| X | Y-reaction value | Y-calculated value | Y-residual | 
|---|
                                                        Use the ‘download’ button to export the table. Be mindful to adjust for dilution factors and replicate averages if not accounted for previously.
                                                    
                                                
                                                    Total absorbance value (ODs):
                                                    
                                                
                                            
                                                    Blank Value 
                                                    
                                                
                                            | ID | Well(s) | Raw OD value(s) | Replicate Average | Infact OData | Conc. | 
|---|
| This report is generated by Proteintech (Proteintech ELISA Data Analyzer). https://www.ptgcn.com/products/elisa-kits/#ELISAAssayCalc | |||||
|---|---|---|---|---|---|
| Experiment name | |||||
| Standard concentration unit | |||||
| Formula | |||||
| a value | |||||
| b value | |||||
| c value | |||||
| d value | |||||
| R^2 | |||||
| ID | Well(s) | Raw OD value(s) | Replicate Average | Infact OData | Conc. |